Delivering HVAC (Heating, Ventilation, Central Air Conditioning) Services & Solutions across India
9650110202|[email protected]|Sell Products

Carrier Cassette AC 1.5, 2, 3, 4 Tons (TR)

Carrier Cassette Air Conditioner with R32 Refrigerant: Available in 1.5 Ton, 2 Ton, 3 Ton, and 4 Ton Units. This carrier ceiling cassette is appropriate for business spaces with room temperatures ranging from 18°C to 32°C. It's available in 18K (1.5 Ton or TR), 24K (2 Ton or TR), 36K (3 Ton or TR), and 45K (4 Ton or TR) units. The nominal cooling capacity varies between models, ranging from 5,300 to 13,480 watts. Carrier ceiling air conditioners include fan, cool, and dry modes, as well as several fan speed options. Cassette AC carrier with user-friendly settings, including a real-time clock, configurable timers, and energy-saving features. The Indian Seasonal Energy Efficiency Ratio (ISEER) provides cost-effective operations. The Robust design of a Carrier cassette AC unit results in dependable and efficient cooling environment. Call for Price.
SKU: SGL65
Free shipping
Delivery date: 3-5 days
*
*
Call for pricing (+91 9650110202)

Features of Carrier Cassette AC:

  1. Auto Mode: Indoor Fan Speed Adjustment.
  • As the name suggests, it automatically varies the fan speed in accordance with the room temperatures.
  • Provides excellent comfort with dynamic airflow adjustment.
  • Provides a steady indoor climate without requiring manual adjustments.
  • Contributes to energy savings.

 

  1. Auto Restart Function: Understanding Power Outage Restarting
  • Automatically restarts the unit with previous settings intact.
  • Provides convenience and peace of mind.
  • Eliminates manual restarting in power-prone areas. Reset the unit, ensuring that the indoor environment remains comfortable without interruption.

 

  1. Sleep Mode: Automatic Nighttime Temperature Regulation
  • Enhances comfort and energy savings.
  • Maintains optimal sleeping temperature.
  • Reduces energy consumption.
  • Prevents excessive cooling or heating.
  • Ensures a comfortable, restful sleep environment.

 

  1. Building Management Systems (BMS) Compatibility: Air Conditioning System Integration
  • Compatible with Building Management Systems via the RS485 communication port.
  • Enables seamless integration into centralized systems.
  • By integrating with the existing BMS, Carrier cassette AC unit can be efficiently monitored and controlled.
  • This efficient monitoring and control results in easy operation and optimized energy use for commercial buildings.

 

  1. Auto Timer: Auto ON/OFF Timer
  • Customizable for convenience.
  • Helps maintain comfort level.
  • Reduces energy consumption when cooling/heating isn't needed.

 

  1. Fresh Air Renewal: Integrates fresh air into rooms
  • Improves Indoor Air Quality (IAQ).
  • By providing a constant fresh air supply it actually enhances well-being and health.

 

  1. Three-Phase Reverse Protection: Phase Sequence Protection for Three-Phase Supply Units
  • The compressor is safeguarded from incorrect phase sequencing.
  • Ensures unit longevity and reliability.

 

  1. Self-Diagnosis: Code-Displaying Errors
  • Simplifies service and troubleshooting.
  • Allows quicker issue identification and resolution.
  • Minimizes downtime and maintenance costs.

 

  1. High-Performance Condensate Drain Pump: Enhanced Pump Design with Safety Float
  • Reduces risk of overflow or water damage.
  • Monitors water levels for reliable operation.

 

  1. Easy Installation: Compact Indoor and Outdoor Units
  • Compact indoor unit with I-shaped suspension brackets.
  • Lightweight outdoor unit.
  • Simplifies the installation process.
  • Flexible design for various settings.

 

  1. Silent Operation: Throttling Device
  • Anti-vibration pads.
  • Specially designed motor.
  • Strategic placement of throttling devices.
  • Minimizes noise for quiet, comfortable environments.

 

  1. Energy Saver Mode: Optimal Comfort Settings Selection
  • Enhances energy efficiency.
  • Automatically optimizes settings for comfort.
  • Reduces power consumption, lowering energy bills.

 

  1. Superior Heat Exchange: Coil Heat Exchange Efficiency Improvement
  • Enhances coil heat exchange efficiency.
  • Improves cooling and heating efficiency.
  • Ensures rapid temperature regulation.
  • Reduces energy use.

 

  1. Easy Maintenance: Air Filter and Blower
  • Easy removal.
  • Accessible service valves.
  • Facilitates quick maintenance.
  • Reduces service time and cost.
  • Ensures consistent unit performance.

 

  1. Corrosion Resistant: Powder-Coated Sheet Metal Casing for Outdoor Units
  • Enhances durability and longevity.
  • Protects against harsh environmental conditions and corrosion.
  • Ideal for various climates.

 

  1. Indoor Unit Design for Maximum Comfort: Optimizes airflow in high-occupancy areas
  • Ensures consistent, comfortable air distribution.
  • Maintains a pleasant indoor environment in crowded spaces.

 

  1. Green Refrigerant: R32 Refrigerator
  • This carrier cassette air conditioner utilizes low GWP refrigerant.
  • Offers efficiency and environmental friendliness.
  • Contributes to lower greenhouse gas emissions.

carrier ceiling ac

cassette ac carrier

Specification of the Carrier Cassette Air Conditioner:

  • Versatile, Efficient
  • Performance Capabilities
  • Caters to various cooling needs
  • Meets building requirements.

 

Carrier Cassette Unit Technical Specifications:

  • Room Temperature Range: 18°C to 32°C.
  • Temperature and Timer Adjustment: Increase or decrease the set temperature/timer value.
  • Mode of Operation: Fan Mode, Cool Mode, Dry Mode.
  • Control Buttons: Toggle Button for Mode of Operation, Unit ON/OFF Button, Louver Swing Operation Button, Timer ON/OFF Setting Button, Daily Clock & Timer Settings Button, Save Button for Settings, Hour/Minute Setting Selection Button, Real Time Clock (12-Hour Format).
  • Indoor Fan Speed Options: Low/Medium/High/Auto.
  • Energy Efficiency Features: Energy Saver Function Selection Button, Sleep Mode Selection Button, Turbo Function Selection Button.
  • Timers and Clocks: Auto ON/OFF Timer Setting Buttons, Real Time Clock Settings Button.
  • Nominal Cooling Capacities:
    1. 18K or 1.5 TR Model: 5,300 Watts,
    2. 24K or 2 TR Model: 7,033 Watts,
    3. 36K or 3 TR Model: 10,551 Watts,
    4. 45K or 4 TR Model: 13,480 Watts.
  • Indian Seasonal Energy Efficiency Ratio:
    1. 1.5 TR Model: 3.52 W/W,
    2. 2 TR Model: 3.55 W/W,
    3. 3 TR Model: 3.20 W/W,
    4. 4 TR Model: 3.05 W/W.
  • Star Ratings:
    1. 1.5 TR Model: 2 Stars,
    2. 2 TR Model: 2 Stars,
    3. 3 TR Model: 2 Stars,
    4. 4 TR Model: 1 Star.
  • Rated Power Supply: 18K and 24K Models: 230V ± 10%, 1 Phase, 50Hz.
  • Weight (Indoor/Outdoor/Grille):
    1. 18K Model: 27.5 kg,
    2. 24K Model: 28 kg,
    3. 36K Model: 32 kg,
    4. 45K Model: 33 kg.
  • Airflow Rate:
    1. 18K Model: 590 CFM,
    2. 24K Model: 730 CFM,
    3. 36K Model: 950 CFM,
    4. 45K Model: 1,070 CFM.
  • Compressor Type: Single Rotary, 36K, and 45K Models: Twin Rotary.
  • Flare Connection Liquid Line: 1/4’’ inch copper pipe for 1.5 Ton and 2 Ton, 3/8” copper pipe for 3 Ton and 4 Ton models.
  • Flare Connection Gas Line: 1/2’’ for 1.5 Ton, 5/8” for 2 Ton and 3 Ton, 3/4" for 4 Ton model.
  • Maximum Piping Length and Elevation: 18K and 24K Models: 20 m, 36K and 45K Models: 30 m, Piping Elevation: 10 m.
  • Refrigerator: R32 Type: R32, Quantity (Factory-Charged): 18K Model: 800 gms, 24K Model: 1,180 gms, 36K Model: 1,220 gms, 45K Model: 1,530 gms.
  • Overall dimensions:
    1. Indoor Unit: for all models: 29.8 cm height x 82.5 cm width x 82.5 cm depth,
    2. Grille Unit: for all models: 3 cm height x 96 cm width x 96 cm depth,
    3. Outdoor Unit: 18K Model: 53.7 cm height x 76.2 cm width x 32.6 cm depth, 24K Model: 66.7 cm height x 90.7 cm width x 32.6 cm depth, 36K Model: 82 cm height x 90.4 cm width x 32.5 cm depth, 45K Model: 82 cm height x 90.4 cm width x 32.5 cm depth.

 

How to Install a Cassette AC Carrier:

Installing a Carrier Ceiling Cassette: A Step-by-Step Guide

 

Pre-Installation Preparation of cassette ac carrier:

  • Gather necessary tools and materials, including measuring tape, ladders or scaffolding, a screwdriver and drill, piping and insulation materials, electrical wiring tools, and protective gear.
  • Ensure the installation area has sufficient space for the cassette unit and a nearby power supply.

 

Determining the Ideal Location for a cassette ac carrier:

  • Make sure that the cassette is placed in the center of the room.
  • Measure the ceiling grid to match the dimensions of the cassette in the installation process of carrier ceiling AC.

 

Installing the mounting plate of the cassette AC carrier:

  • Position the mounting plate in the selected area of the ceiling grid.
  • Secure the mounting plate to the ceiling using screws and anchors.

 

Preparing the Piping and Drainage for the Carrier cassette air conditioner:

  • First of all, make sure to connect the copper pipe (refrigerant pipe) to the indoor unit.
  • Prepare the drainage system to effectively remove condensation from the unit.

 

Installing the Ceiling Cassette Unit:

  • Carefully lift the unit onto the mounting plate.
  • Use the brackets and screws, and then secure the indoor unit to the mounting plate.

 

Connecting the Electrical Wiring:

  • Turn off the power supply and connect the power supply wiring to the unit according to the installation manual.
  • All electrical connections should be tightly fixed and fully secured.

 

Testing the Unit:

  • Turn on the ceiling cassette and set it to the desired temperature.
  • Check for proper airflow and unusual noises.
  • Inspect the refrigerant piping and drain pipes for any signs of leakage.

 

Final Checks and Maintenance Tips:

  • Go through a final inspection in order to check that all components are properly installed.
  • Regularly clean the air filters and inspect the unit for signs of wear or damage.
  • Schedule professional maintenance annually to check the refrigerant levels and inspect the unit’s components.

 

Call for Price.